AUZ

The AUZ unidirectional tunnel jet fans deliver high thrust and robust performance for road and rail tunnels.
Built on the advanced NOVENCO ZerAx® platform, they achieve high efficiency with smaller fan selections, lower power consumption, and reduced sound levels. In addition to standard ventilation, the AUZ fans support smoke control ventilation and are tested and approved for smoke exhaust with variable speed drives (VSD).
The design features circular silencers and the proven NOVENCO ZerAx® axial fan technology.

Product highlights
@contentitem.EvtBillede.Name
Above ErP compliance
NOVENCO fans surpass the EU Ecodesign (ErP) requirements and deliver higher efficiency with consistent performance. This results in lower power use, reduced operating costs, and a more sustainable choice for modern ventilation systems.
@contentitem.EvtBillede.Name
EN 12101-3:2015 certified
NOVENCO ZerAx® smoke fans are tested and certified for operation with variable speed drives for temperatures at up to 300°C during 2 hours according to EN 12101-3 for powered smoke and heat control fans.
High thrust and efficiency
ZerAx® technology ensures exceptional thrust performance, enabling smaller fan sizes and reduced energy use.
Fire-safety approved
F200 and F300 certifications allow reliable smoke extract operation with VSD during tunnel fire scenarios.
Durable construction
Hot-dip galvanised or stainless steel casing and silencer options with aluminium impellers ensure long service life in demanding tunnel environments.
AUZ_1.png
AUZ_2.png
AUZ_3.png
AUZ_4.png
Next image
Previous image
AUZ_1.png
AUZ_2.png
AUZ_3.png
AUZ_4.png
Product highlights
@contentitem.EvtBillede.Name
Above ErP compliance
NOVENCO fans surpass the EU Ecodesign (ErP) requirements and deliver higher efficiency with consistent performance. This results in lower power use, reduced operating costs, and a more sustainable choice for modern ventilation systems.
@contentitem.EvtBillede.Name
EN 12101-3:2015 certified
NOVENCO ZerAx® smoke fans are tested and certified for operation with variable speed drives for temperatures at up to 300°C during 2 hours according to EN 12101-3 for powered smoke and heat control fans.
High thrust and efficiency
ZerAx® technology ensures exceptional thrust performance, enabling smaller fan sizes and reduced energy use.
Fire-safety approved
F200 and F300 certifications allow reliable smoke extract operation with VSD during tunnel fire scenarios.
Durable construction
Hot-dip galvanised or stainless steel casing and silencer options with aluminium impellers ensure long service life in demanding tunnel environments.
Related products

The AUZ tunnel jet fans, based on the highly efficient ZerAx™ platform, are engineered for tunnel applications and with impeller diameters ranging fromØ900 to Ø1250 mm. These jet fans offer superior thrust efficiency for both daily ventilation and emergency smoke control. 

The unidirectional design features standard 1220 mm round silencers on each side, with customization options available for different silencer lengths or inner cores for enhanced sound attenuation, along with optional wire guards and outlet cones. 

As a standard, the fan casing and silencers are galvanized steel, meeting corrosion category C3, but stainless steel and higher corrosion categories (C4 or C5) are available upon request for increased protection. 
Corrosion classes in accordance with EN-ISO 12944-2:2017.

Certifications
  • F200 and F300 smoke extract approvals with VSD in accordance with EN 12101-3:2015.
  • Ff300 fans have been tested at 300°C during 2h.
Performance

Built upon the ZerAx® platform, these AUZ tunnel jet fans deliver extremely high thrust efficiencies coupled with optimized aerodynamic performance.

Sizes

Four impeller diameters from Ø900 to Ø1250 mm ensure correct sizing for tunnel ventilation demands.

Fan casing materials & corrosion categories
  • Static parts in hot-dip galvanised sheet steel or stainless steel.
  • Corrosion classes: C3 standard; C4 or C5 optional in accordance with EN/ISO 12944-2.
Accessories & variations

Optional inlet wire guard and efficient aerodynamic outlet cone.

Catalogues
Brochures
Manuals
Declaration of performance

The AUZ series offers four impeller diameters, ranging from Ø900 to Ø1250 mm, with measured thrust up to 1750 Newtons (N).

Need help with your next project?
We are here. 

Contact us for inquiries and technical support
Our engineering team provides expert guidance and delivers custom technical solutions for clients worldwide.

Name*
Company*
Email address*
Phone*
Please describe your inquiry

Related industries

Hero tunnel_website.png
Tunnels
Our tunnel jet fans are manufactured in Denmark to the most stringent standards, earning recognition for their uncompromising quality and reliability at high temperatures. Featuring modern design and advanced technologies, our systems ensure high efficiencies, dependable operation, and low sound levels in demanding environments.
Smoke-free escape routes_website.png
Smoke-free escape routes
High-rise buildings require robust life-safety systems to ensure safe evacuation in case of an emergency. Smoke is the leading cause of fatalities in building fires.

Related industries

Hero tunnel_website.png
Tunnels
Our tunnel jet fans are manufactured in Denmark to the most stringent standards, earning recognition for their uncompromising quality and reliability at high temperatures. Featuring modern design and advanced technologies, our systems ensure high efficiencies, dependable operation, and low sound levels in demanding environments.
Smoke-free escape routes_website.png
Smoke-free escape routes
High-rise buildings require robust life-safety systems to ensure safe evacuation in case of an emergency. Smoke is the leading cause of fatalities in building fires.
Schako Group
Admeco Novenco Reven Schako Schneider Sirocco Smitsair